Root-inspired glue joins 1mm blood vessels in under 9 minutes
A plant-root-inspired adhesive seals blood vessels about a millimeter wide without a single stitch, cutting average joining time in rats to under nine minutes from roughly 39. The silicone glue grips wet, pulsing tissue with needle-armed anchors and carries a battery-free sensor that monitors pulse and transplanted hearts. If it holds up clinically, it could reshape small-vessel surgery.
- Original source: phys.org.
- The source published it on Nov 28, 2026 at 5:00 PM.
- Not verified by major outlets. This story may be false.
- No second outlet has reported it yet. Treat it as a single-source claim.
Sewing a blood vessel barely a millimeter wide is fussy, slow work — and every stitch risks scraping the delicate lining inside. A new adhesive built from a plant-root blueprint skips the needle entirely, cutting average joining time in rats to under nine minutes, down from about 39 with conventional stitching, according to the study published in Science.
The glue itself is silicone-based and water-repelling: it pushes surface water aside and forms chemical bonds with tissue, solving a problem that has sunk earlier surgical adhesives in wet, blood-filled settings. Gripping comes from tiny 3D-printed anchors with four needlelike arms embedded in the material, which interlock with the vessel wall the way roots hold a plant in wet soil. A temporary cuff holds the vessel ends in line while the join sets, and the adhesive stays outside the channel carrying blood, limiting the chance glue drifts into circulation.
Researchers led by Wen Zeng of Third Military Medical University in China and Malcolm Xing of the University of Manitoba tested the system in rat carotid arteries roughly 1 millimeter across. The faster procedure produced less bleeding and preserved more of the vessels' inner lining than stitching, they report. Ten months later, small groups of rats showed less thickening of the inner wall and more even blood flow at the glued joins than at the stitched ones — a meaningful difference, since excess wall thickening can narrow an artery and choke off circulation.
Woven into the adhesive is a battery-free wireless sensor that acts as a post-op check-up tool. Wrapped around a vessel, it converts the wall's tiny pulse-by-pulse movements into changes in electrical response, which an external reader picks up without an implanted power source. When the team deliberately narrowed rat arteries by varying degrees, the pulse signals weakened and shifted shape as the restriction grew, and machine-learning analysis used those changes to flag the narrowed vessels.
In a separate experiment, the researchers hooked donor hearts to blood vessels in rats' necks and watched the sensors record beating for three months. Signal strength and rhythm separated working grafts from failing ones, matching ultrasound readings that showed failing transplants had lost heart-wall motion while healthy ones kept contracting.
The system has so far only identified existing narrowing and graft dysfunction in animals. The team says further testing must show how reliably it performs across vessel sizes and surgical sites, and whether it can flag complications early enough to save a repair or a graft. They also propose future uses beyond blood vessels: repairing nerves, attaching tendons, or sealing leaks around the brain and spinal cord.
TopicsWen Zeng · Malcolm Xing · Third Military Medical University · University of Manitoba · Science · Fangchao Xue
Source: phys.org
Written by AI from verified reporting.
More stories
- Health & science cbsnews.com Caught by @ryders 4 viewsMeasles deaths hit 14 as US loses elimination status for first time in 26 years
- Health & science x.com 3 viewsChinese Scientists Build Tech to Turn CO2 Into Breathable Oxygen for Mars
- Health & science theguardian.com Caught by @madesetiawanMenopause hormone scripts jump 141% while estrogen patches run short
- Health & science tech.yahoo.comFDA clears Neuralink for first pivotal US brain implant trial

